Climatronics recommends that system maintenance begins by establishing a schedule for periodic system reviews. These reviews should be conducted monthly and semi-annually. It may be useful after the system is first installed, to do some of the checks more frequently until the system operation is completely familiar.
Monthly site checks are reviews of the system to make sure that it is reporting reasonable data. Should this check indicate that there is a problem with the system, corrective maintenance should be performed.
Periodic maintenance is work to be performed every six months or more frequently should your operational experience indicate the need. This should keep your system operational and prevent non-scheduled outages.
|
| |
|
|
100075 |
Wind Speed Sensor |
Check to see that the cups are turning. |
100076/102139 |
Wind Direction Sensor |
Check to see that the data appear reasonable. |
100093 |
Temperature Sensor |
Compare data to psychrometer. |
102273/101943 |
Relative Humidity Sensor |
Compare data to psychrometer. Check sensor filter for dirt/dust. Clean or replace as necessary. |
100325 |
Motor-Aspirated Shield |
Clean front inlet and rear housing. |
102318/102319 |
Pyranometer |
The outer dome must be cleaned and inspected. Check it to ensure that the instrument is level and that there is no condensation inside the dome. |
100097/100508 |
Precipitation Gauge |
Check funnel and screen, and remove any debris. |
|
|
| |
|
|
100075 |
Wind Speed Sensor |
Replace sensor on tower with spare. Use wind speed test fixture to check speed, comparing both the digital and analog output. Replace bearings on sensor removed from tower. |
100076/102139 |
Wind Direction Sensor |
Replace sensor on tower with spare. Replace bearings on sensor removed from tower. Use linearity fixture when re-assembling the sensor. |
100093 |
Temperature Sensor |
Remove sensor from aspirator and wipe any dust or dirt from sensor with a clean cloth. Replace in aspirator when finished.
|
102273/101943 |
Relative Humidity Sensor |
Remove sensor from aspirator. Look at sensor to be sure it is clean. Compare data to psychrometer. Recalibrate if necessary. |
100325-5 |
Motor-Aspirated Shield |
Clean aspirator of any dirt or dust. Feel fan exhaust to make sure fan is running.
|
102318/102319 |
Pyranometer |
Replace the desiccant twice a year in humid areas, or as required in other locations.
|
100097/100508 |
Precipitation Gauge |
Removal funnel. Clean funnel, bucket
assembly, drain tubes, drain line, and inner funnel. Oil pivot bearing with a drop of light oil. Check the calibration per the manual's calibration procedure.
|